SDB Home
Products
Home
OIS Home

CONVERTER of SURPLUS PRESSURE of GASES and LIQUIDS



SPECIFICATIONS
Value
Range of operating pressures, KG/cm2
0.. 0,4; 1; 2,5; 10
Output signal, mA
4.. 20
Instrument error, (% from the range)
No more than + 0,5
Operating temperatures span, centigrade
- 40.. + 60
Voltage of the power supply (DC), V (Es)
24 (+ 6, -13)
Maximum load impedance, Om Under Es = 30 V
No more than 1000
Consumption current (max) mA
No more than 35
Overall dimensions, mm
No more than D48 (36) x85
Maximum pressure overload, P
1,5

Rnmax = (Es - 3)/0.020; (Rn = Rl + Rx)

Where: Rl - is resistance of the line, Rx - is resistance of the exemplary resistor.

The note:
A) Converter is provided with the system for protection from incorrect connection of the supply voltage's polarity.
B) At the exit "ALARM" converter will provide monitoring over open-circuit of a measuring line or Exceeding Rn max.
C) The Converter is not designed for operation on an inductive load.